Managing a white mature cataract

There are several ways to classify white cataracts.

From a surgical perspective, the classification below is particularly useful because it directly influences the intraoperative approach.

Types of White Cataract

Type Characteristics Intraoperative Risk
Type 1 Intumescent cataract with abundant liquefied cortical material and elevated intralenticular pressure. High risk of the Argentinian flag sign when opening the capsule.
Type 2 White cataract with little liquefied cortical material. Little additional intraoperative risk.
Type 3 Fibrotic anterior capsule, often with minimal cortical material. Creating a capsulorhexis by tearing may be difficult or impossible.

Argentinian Flag Sign

The Argentinian flag sign refers to radial extension of the anterior capsulorhexis during cataract surgery.

The name comes from the characteristic appearance: the central, blue-stained portion of the capsule is flanked by two white bands of cataractous lens material, resembling the Argentinian flag.


Mechanism

The underlying mechanism is a sudden pressure change within the capsular bag.

When the anterior capsule is opened, liquefied cortical material may escape.

  • This creates a posterior-to-anterior pressure wave, pushing the nucleus forwards.

  • As a result, the capsulorhexis may suddenly extend radially, usually towards the equator and sometimes into the posterior capsule.


Risk Factors

The risk of the Argentinian flag sign is greater in the following situations:

  • Type 1 white cataract:
    Abundant liquefied cortical material and elevated intralenticular pressure.

  • Reduced anterior chamber pressure:
    For example, leakage of viscoelastic through the incision reduces the counterpressure against the anterior capsule.


Clinical Significance

Recognising these risk factors before opening the capsule is essential.

Careful control of anterior chamber pressure and controlled decompression of the lens can substantially reduce the risk of a capsular tear.


Intraoperative Assessment and Management

The following step-by-step approach helps identify the type of white cataract and guide its management:

  1. Create two paracenteses.
    Avoid making the main incision at this stage to prevent loss of anterior chamber pressure.

  2. Inject Vision Blue to improve visualisation of the anterior capsule.
    Then wash out the dye completely with BSS.

  3. Fill the anterior chamber with a dispersive or highly cohesive viscoelastic, such as Healon GV or Healon V.

  4. Avoid shallowing of the anterior chamber at all times.

  5. Make a central puncture in the capsule using a fine needle or a 1 mm blade.

    • In type 3, this may be difficult or even impossible because of capsular fibrosis.

  6. Introduce a Rycroft cannula through a paracentesis and advance it beneath the anterior capsule, almost to the equator, before starting aspiration.

    • Type 1: Milky, liquefied cortical material is aspirated, and the capsule often contracts.

    • Type 2: Little change is seen, as there is very little liquefied material.

    • Repeat through the second paracentesis.


Subsequent Surgical Steps

  • Types 1 and 2:
    Following aspiration, surgery usually proceeds as in a routine cataract case.
    The white cataract is generally not particularly dense. However, the cortex often has little structural integrity, so little cortical material may remain after emulsification of the nucleus.

  • Type 3:
    Initiating the capsulorhexis with forceps is often difficult or impossible.
    In this situation, use intraocular scissors to make an initial cut in the capsule.
    Additional paracenteses may be needed to improve access and control.


Summary

  • Type 1: Intumescent cataract — elevated pressure and milky, liquefied cortical material → risk of the Argentinian flag sign.

  • Type 2: Less liquefied cortical material → generally amenable to a routine surgical approach.

  • Type 3: Fibrotic capsule → technically challenging capsulorhexis, often requiring alternative instruments.

 

 

 

 

 

 


Was dit artikel behulpzaam?

U heeft nog vragen? Contacteer Ons